Datacenters

Where your data actually lives

Lineserve runs inside carrier-neutral, Tier III data centres on the continent — not a distant edge region of a foreign cloud. Real facilities, real redundancy, in the metros your users are in.

3

live regions

Tier III

facilities

Carrier-neutral

connectivity

<6 ms

latency within each metro

The footprint

Three metros, on the ground today

Each region is a physically distinct facility with its own power, cooling, connectivity, and network endpoint. Choose where your workloads and data live.

Live

Nairobi

Kenya · ke-1a

2 ms

latency within metro

Live

Dar es Salaam

Tanzania · tz-1a

6 ms

latency within metro

Live

Lagos

Nigeria · ng-1a

4 ms

latency within metro

Facility detail

Inside our regions

Certifications and standards below belong to the facility operator; Lineserve operates within these carrier-neutral, Tier III facilities.

Nairobi (ke-1a)

Location

Nairobi, Kenya

Facility

[Facility operator name], Tier III, carrier-neutral

Power

Redundant A+B feeds, UPS-backed, [generator] backup

Cooling

N+1, [hot/cold-aisle containment]

Connectivity

Carrier-neutral; access to [East African subsea cable systems]

Storage endpoint

ke-1a.s3.lineserve.net

Dar es Salaam (tz-1a)

Location

Dar es Salaam, Tanzania

Facility

[Wingu Data Centres], Tier III, carrier-neutral

Power

Redundant A+B feeds, UPS-backed, generator backup

Cooling

N+1 precision cooling

Connectivity

Carrier-neutral; access to [regional subsea cable systems]

Storage endpoint

tz-1a.s3.lineserve.net

Lagos (ng-1a)

Location

Lagos, Nigeria

Facility

[Digital Realty / Medallion], Tier III, carrier-neutral

Power

Redundant A+B feeds, UPS-backed, generator backup

Cooling

N+1 precision cooling

Connectivity

Carrier-neutral; access to [West African subsea cable systems]

Storage endpoint

ng-1a.s3.lineserve.net

Built for uptime

The standards behind every region

Our regions operate in facilities engineered for continuous availability — the layers that are expensive and slow to build, already in place.

Tier III facilities

Concurrently maintainable power and cooling, so maintenance never means downtime.

Redundant power

Dual A+B feeds, UPS protection, and generator backup to ride through grid faults.

Resilient cooling

N+1 precision cooling with containment to hold temperature under full load.

Physical security

Access control, CCTV, and staffed, audited entry to every space.

Fire detection & suppression

Early-warning detection and suppression systems protecting the floor.

24/7 monitoring

Power, environmental, and network monitoring around the clock, with on-site response.

Connectivity

Carrier-neutral, close to the cables

Our facilities are carrier-neutral, so you're never locked to a single network. Blended local IP transit keeps latency low and traffic on the continent, with cross-connects to the carriers and peers you need.

Carrier-neutral

Choose among multiple upstreams and peers within the facility.

Local IP transit

Blended, low-latency transit from regional providers, with room to scale.

Subsea cable access

Proximity to the major East and West African subsea cable systems.

Cross-connects & peering

Direct links to carriers, IXPs, and your own cabinets.

Sovereignty

Your data stays on the continent

For regulated, sensitive, or public-sector workloads, jurisdiction matters. Because our facilities are physically in-region, your data can stay in the country you choose — under laws you understand, close to the users it serves.

Talk to Sales about data residency

What's next

More regions, zone by zone

We're extending the footprint across the continent, placing infrastructure closer to more users. These zones are in progress.

Expansion zonesUganda · ug-1a · in progressSouth Africa · za-1a · in progressGhana · gh-1a · in progress

Put your workloads where your users are

Tier III facilities, redundant everything, and data that stays in-country — with local billing and support.

Talk to Sales

99.9% uptime SLA · Carrier-neutral · Data stays in-country